IG4000 Action _ Rev 1.1
NC / NO / Polarity
- Set-up for Power Off Status
- NC (Normal Close) – maintain switch connection
- NO (Normal Open) – maintain switch disconnection
*Definitions according selection of connecting ports
- Set-up for Operation on Power On Status
- Polarity – Settled signal for initial status and operation status
- Delay Time – Keep open for a settled time after authentication, turn back to after settled time pass
*Definitions according to set with special setting card
- Table by Door Action
|
|
POLARITY |
|
|
|
1 |
0 |
|
|
|
LOCK |
NO |
NC |
Generally Power On standby status is closed |
|
UNLOCK |
NC |
NO |
Door Open status during fixed time |
- Table by Connecting Port
|
Port |
Polarity 1 |
Polarity 0 |
||
|
Stand by status |
Control |
Stand by status |
Control | |
|
NC |
Open |
Connect |
Connect |
Open |
|
NO |
Connect |
Open |
Open |
Connect |
*Connection=On
*Open=Off
- IG4000 Default Setting
- Polarity: 0
- Delay Time: 3000 msec
Scenario 1 (Emergency exit_1)
- Lock
- Lock keep being opened in case Control Wires are Opened (Disconnected)
- Scenario (Emergency Exit)
- Door power off - Unlock
- Stand by status - Lock
- Door Authentication - Unlock for a while
- Install & connect
- Connect to NO port of IG4000
- Polarity : 1
Scenario 1 (Emergency exit_2)
- Lock
- Lock keep being opened in case Control Wires are Closed (Connected)
- Scenario (Emergency Exit)
- Door power off - Unlock
- Stand by status - Lock
- Door Authentication - Unlock for a while
- Install & connect
- Connect to NC port of IG4000
- Polarity : 1
Scenario 2 (Common Facilities)
- Facilities Type
- Lock keep being opened in case Control Wires are Opened (Disconnected)
- Scenario
- Door power off - Lock
- Stand by status - Lock
- Door Authentication - Unlock for a while
- Install & connect
- Connect to NC port of IG4000
- Polarity : 0
Scenario 3 (Storage)
- Lock
- Lock keep being opened in case Control Wires are Closed (Connected)
- Scenario (Storage)
- Door power off - Lock
- Stand by status - Lock
- Door Authentication - Unlock for a while
- Install & connect
- Connect to NO port of IG4000
- Polarity : 0
Scenario 4 (Elevator all floors)
- Product : Elevator Button Control
- Button push action in case Button Common Signal Wire is Closed (Connected)
- Scenario (Elevator Button)
- Power off - button is activated
- In stand by status - button isn’t activated
- Authentication - Button is activated for a while
- Install & connect
- Connect to NC port of IG4000
- Polarity : 1
Door Lines Connection
Elevator Lines Connection
- Generally elevator has 2 buttons: up and down
- There are 2 lines for each of the button, totally 4 lines and two of them should to be connected into the common IG4000 should be connected with this common button line
|
Pin Name |
Abbreviation |
Explanation |
|
Pin 1 |
+12V |
DC 12V power connect |
|
Pin 2 |
GND |
GND |
|
Pin 3 |
TMN_T |
Door open Switch input Tx Data (Option) |
|
Pin 4 |
TMN_R |
Rx Data (Option) |
|
Pin 5 |
NO |
Normally Open Terminal |
|
Pin 6 |
COM |
Relay Common Terminal |
|
Pin 7 |
NC |
Normally Closed Terminal |